Connection and FW update
Connection to the ECU
Bluetooth
Bluetooth - convenient way to connect to the ECU. Android application is connected via Bluetooth.
Pair with "Invent EMS" device. PIN 0000. Bluetooth COM port will appear in the system.
Warning
Firmware update and analyzer do not work via Bluetooth
USB
USB is used to configure, update the firmware, and to use waveform analyzer.
Important
USB is galvanically isolated with the ECU. To connect, you need 12 volts supply to the ECU.
Remote connection
Commander can talk to the ECU over the network instead of a serial port. The protocol is carried over UDP, which allows tuning and diagnostics from another room or over the internet.
Select Remote connection in the port list instead of a COM port, then press ON.
Commander sends the data to UDP port 56756 on the local machine, so a bridge application that forwards this traffic to the ECU (Ethernet / Wi-Fi adapter, VPN or tunnel) has to be running on the computer.
Important
Firmware update over the remote connection isn't working
Warning
A network link is slower and less predictable than USB. Reading calibrations take longer.
Connection procedure
- Select COM port in Commander and press ON.
- When using Bluetooth - wait a few seconds to establish the connection. USB connects instantly.
- If succeeded, Commander will read all calibrations from the ECU.
Warning
If you see a message: The Commander version does not match the firmware version - you must use the correct version of the Commander for a successful connection.
Firmware update
The ECU is designed in such a way that it cannot be killed by updating the firmware. While power is supplied, connection is established, and processor is working, you can reupload the firmware again.
Warning
Firmware update is possible only via USB cable. It does not work via Bluetooth or a remote connection.
Warning
Loading the firmware erases calibrations from the memory
- Connect to the ECU via USB, using current Commander version
- IMPORTANT Read the calibrations from the ECU and save to the file.
- Open tab Parameters - Firmware
- Select the desired firmware type
- Press Update and open the firmware file.
- Wait for the download to complete and close Commander
- Open the new Commander version and connect to the ECU
- Open the calibration saved earlier
- If Commander issued a warning about versions mismatch - review the calibrations, you will probably need to configure new parameters manually
- Save the calibration to the ECU.
- Wait 10 seconds after completing and turn off the ignition.
If update failed
You will no longer be able to connect to the ECU - you will see an endless Searching status. This is expected, because there is no firmware inside.
Set your laptop to a performance mode. Close all other applications, including messengers.
- Turn off the ignition.
- Select COM port, but do not connect to the ECU.
- Press Update and select the firmware file.
- Wait for the message Searching and quickly turn on the ignition.
- Download should start.
If nothing helps
- Check the 12V power to the ECU
- Check whether the COM port is correctly selected.
- Try another laptop
- Try another USB cable