ECU is dust and splashproof. It cannot withstand continuous water contact or pressurized water. Do not install ECU with cable upwards. In this case, water and moisture will flow off the cable into ECU.

Do not install ECU close to the heat sources (turbochargers, exhaust system, cooling radiators). ECU needs sufficient cooling, especially for drive-by-wire system.

Ground connection

All ground wires must be securely connected at one point.

The sensors ground SGND must be connected to the same point. SGND should only be connected to common ground at this point.

Warning

Do not operate the unit without connecting all ground pins. This can lead to PCB damage.

Wire size

The table shows the long-term load current in amperes.

Separate wire

20°C 30°C 50°C 80°C
0.5 mm2 17 16 14 9
0.75 mm2 22 21 17 12
1.0 mm2 26 25 21 15
1.5 mm2 33 32 27 19
2.5 mm2 45 43 37 26
4.0 mm2 61 58 50 35
6.0 mm2 80 77 66 47
16.0 mm2 149 142 122 89

Up to 7 wires together

20°C 30°C 50°C 80°C
0.5 mm2 9.3 8.8 7.7 4.9
0.75 mm2 12.1 11.5 9.4 6.6
1.0 mm2 14.3 13.7 11.5 8.2
1.5 mm2 18.1 17.6 14.8 10.5
2.5 mm2 24.7 23.7 20.3 14.3
4.0 mm2 33.5 31.9 27.5 19.2
6.0 mm2 44.1 42.3 36.3 25.8
16.0 mm2 81.9 78.1 67.1 48.9

Example of the wire harness