Separate CLT sensor

If you encounter issues with the OEM engine temperature sensor, such as fluctuating readings or a missing or damaged OEM ECU, consider connecting an independent temperature sensor.

It is recommended to use a 2-wire sensor from an injection engine, with a resistance of 2-3 kΩ at 20°C.

Connect the SGND wire of the new sensor in parallel with the GND wire of the MAP sensor

Enable the manual mode and separate sensor options

If calibration of the sensor readings is required, please follow these steps:

  1. Click the calculator icon adjacent to the table.
  2. Set the sensor voltage at three specific reference points:
  3. 0°C (temperature of ice water)
  4. Room temperature (approximately 20°C)
  5. 100°C (boiling point of water)

TPS sensor

You can use a modern throttle position sensor (TPS) instead of the original throttle switches. The 5V power supply and ground must be connected from the MAP.