Skip to content

Separate CLT sensor

If you have problems connecting to the OEM engine temperature sensor, the sensor readings are fluctuating, the OEM ECU is missing or damaged, you can connect an independent temperature sensor.

It is advisable to use a 2-wire sensor from an injection engine with a resistance of 2-3 kΩ at 20°C.

Connect the SGND wire of the new sensor in parallel with the GND wire of the MAP sensor

Enable the manual mode and separate sensor options

If necessary, calibrate the sensor readings.

To do this, click the calculator button next to the table and set the voltage from the sensor at three points. It is convenient to use the following points: - 0°C (water temperature in ice) - room temperature (about 20°C) - 100°C (boiling point of water),